STC/Firewall Inspections (Build Henrico)

pokynone

 

COMMONWEALTH OF VIRGINIA

COUNTY OF HENRICO

DEPARTMENT OF BUILDING CONSTRUCTION AND INSPECTIONS

                                NOTICE

 

 

TO: Residential Contractors                                                                                                  SUBJECT: STC/Firewall Inspections

FROM: Building Official                                                                                                          DATE: Updated  July 14, 2022

Section 113.3 of the Virginia Residential Code requires framing and insulation inspections for Sound Transmission Classification (STC)/Firewalls that separate attached dwelling units prior to installing any concealing materials.  The inspections may be requested via the Build Henrico Customer Portal at Build Henrico Log-In.   Both the Firewall Framing and the Firewall Insulation inspections require that the complete set of approved construction plans be on site for use by the inspector.

A third party inspection may also be used to satisfy the required Firewall Framing and Firewall Insulation inspections.  The following conditions shall apply when using third party special inspections.

  1. The third party inspections must be performed by, or under the supervision of, a Virginia registered design professional (i.e., Professional Engineer or Architect).
  2. A Firewall Framing and Firewall Insulation inspection shall be requested by the permit holder or the registered design professional no later than 7 a.m. on the day that the inspections are to be performed.  A message shall be entered on the inspection request to indicate that the framing and insulation inspections are being performed by the registered design professional and the approximate time of their inspection.  Both the Firewall Framing and Firewall Insulation inspections require that the complete set of approved construction plans be on site for use by the third party inspector.  A Residential Building Inspector or Plan Review Engineer may visit the site to audit the inspection.
  3. The registered design professional’s report of the completed third party inspection shall be filed with the Department of Building Construction and Inspections prior to obtaining a final inspection for either of the dwelling units served by the STC/Firewall.  A .pdf version of the inspection report shall be uploaded to the building permit as a supplemental document on the Build Henrico Portal. The department will not accept photocopy or faxed reproductions of completed inspection forms. The permit holder shall request the applicable inspection on the Build Henrico portal and specify on the inspection request that the third Party inspection report has been posted to the permit.
  4. The registered design professional and contractor will be notified in the event that the inspection report is rejected.  The registered design professional’s report shall indicate the date, start and end times of the inspections.  The report shall also verify the materials used to construct the wall (e.g., studs, insulation, sheathing, fasteners, etc.), the method of construction applicable to the specified design, and confirmation that the wall was observed to conform with the approved plans.

Any STC/Firewall design that was required to be specified prior to issuance of the building permit and was completed prior to obtaining the Firewall Framing and Firewall Insulation inspections shall be subject to a field sound transmission test conducted in accordance with ASTM E336.  The test shall be conducted by, or under the supervision of, a Virginia registered design professional.  The test results shall confirm compliance with the STC rating specified in the approved construction documents and the Plan of Development/Subdivision approval.  The field test report shall be submitted to the Residential Building Inspections Supervisor and be approved prior to obtaining an approved final building inspection and issuance of the Certificate of Occupancy.  The ASTM E336 test procedure will not be accepted as an alternative to the required Firewall Framing and Firewall Insulation inspections for any building permit application filed on or after June 1, 2005.

Fire-rated and Sound Transmission classified floor-ceiling assemblies that are located between dwelling units will continue to be inspected during the routine framing and insulation inspections requested for each respective dwelling unit.

Please call our offices at (804) 501-4360 between 8:00 a.m. and 4:30 p.m. if you have any questions regarding these inspection procedures.

Gregory H. Revels, CBO
Building Official

Contact Us

Building Inspections

Physical Address
Department of Building Construction and Inspections
4301 East Parham Road
Henrico, VA 23228

Phone
(804) 501-4360
Automated Permit System
(804) 501-7770

Mailing Address
Department of Building Construction and Inspections
P. O. Box 90775
Henrico, VA 23273-0775

 
Google Translate Icon

Translate